If you already have hot fixes installed on version 7.0, you should review this document carefully to ensure that the hot fixes you have installed are included in this Service Pack.
Citect process analyst pen assinment update#
To resolve the issue: Go to Graphics Builder Select Tools->Options from the menu Uncheck „Fast Update Pages‟ Select Tools->Update Pages Start Citect runtime then the IDC Restart Citect now?” In some cases after installing the SCADA service pack and restarting an IDC instance, this error will appear. 50117 IDC error “Page „page_name‟ has been compiled against an incompatible version of the user library functions. Customers affected by this issue are advised to contact Citect Support for a hotfix that corrects this issue. 44040 Digital tags return incorrect values when Scheduled IO devices are restarted After the release of this service pack, an issue was discovered that could result in incorrect values being displayed on screen when Schedule IO devices are in use and a server is restarted. Recompiling the Example project will resolve this issue. The error concerns the "_PROJECT" database and is reported through a popup dialogue. \Citect\CitectSCADA IDC 7.0\ 46103 Failed to load Database _PROJECT pop up error If the Example project (not the CSV_Example project) has been recompiled prior to upgrading to Service Pack 2 (or higher), then a runtime error results when running up the Service Pack.
Citect process analyst pen assinment full#
40882 v7 IDC crashes after uninstalling v7 service pack To avoid this crash, perform a full compile of the project and remove all files under the following directory after uninstalling the service pack and before starting the IDC. To resolve, use the new drop down option(s) available in Service Pack 2 and above. trend tags, reports, events) may experience Invalid time format compile errors after upgrading to Service Pack 4. 36365.2 Invalid time format compile error after upgrading from v7.0 Service Pack 1 French and German machines that have been upgraded to v7.0 Service Pack 1 and use the Period field in any Project Editor form (e.g.
Citect process analyst pen assinment driver#
To resolve and reinstate protocols in the drop down list, reinstall their corresponding Driver Pack(s).
Citect process analyst pen assinment drivers#
Table 2 - Known Issues Issue Number Issue Title and Description 36365.1 Protocols are missing from the IO Devices form after installation of a v7 service pack French and German machines may experience this issue if drivers have been installed after the original CitectSCADA install. This Service Pack contains the known issues described below. Day of the month format changes from “DD” to “DDter”. Days of the week change from German to English. German Day of the month format changes from “DD.” to “DDter”. Day of the month format changes from “DDeme” to “DDe”. Month names change from lower-case to title-case. Days of the week change from French to English.

Table 1 - French and German Period field changes in Service Pack 4 Upgrading from v7.0 release Upgrading from v7.0 Service Pack 1 French No change. For more information see issues 36365.5.2 on the following page, and Table 1 below. However, users upgrading from Service Pack 1 may need to update their projects to match the new drop down options. The majority of French and German customers, who are not currently running Service Pack 1, do not need to reconfigure their projects. These changes, with the exception of German day of the month, were reversed in Service Pack 2. In v7.0 service pack 1, an attempt was made to translate all Project Editor Period field text strings for French and German installs into their localised form. Customers should also do an Update Pages (in Graphics Builder→Tools→Update Pages) on any projects using CSV_Include templates.

Ensure that the Incremental Compile menu option (in Project Editor→Tools→Options) is not checked, or set INCREMENTALCOMPILE=0.

To force an upgrade, edit the Citect.ini file and set UPGRADE=1. Failure to do so will result in conflicting database size messages. This document describes the modifications and fixes made in CitectSCADA version 7.0 Service Pack 4 as well as providing installation information.Īs per recommended practice, all projects should be backed up prior to commencing the Service Pack installation.Īll projects must be upgraded and recompiled after installing this Service Pack.